Automatic head valve Iron & Manganese removal filters

Filters for the treatment of iron and manganese removal from water. Specially designed for industrial, commercial and domestic use for small and medium flow rates.

The IMA water iron reduction equipment with automatic head can be used for any industrial and well water treatment application where iron removal below the minimum values required by the administration (less than 200 ug/l) is required. With IMA water filters this reduction is achieved after sizing and installation of the appropriate model for the amount of iron and the flow rate to be treated.

 

Manufacturing characteristics of iron and manganese removal filters

  • Fiberglass reinforced polyester body with capacity to withstand up to 8 bar.
  • Magnum control head for automatic operation and washing.
  • Chronometric control for automatic washing.
  • Specific filtering load for the treatment of iron and manganese in the water.
  • Temperature from 0 to 35ºC.

 

Included equipment:

  • Connection
    • 2.5 inch filters diameter (330 mm)
    • 4 inch diameter filters (410,550 mm)
  • Maximum working pressure 150 psi.
  • Working temperature 0ºC to 35ºC
  • Katalox Filter: Recommended PH 6-9

If Fe+Mn concentration is high. Additional oxidation treatment may be necessary.

  • Manganese dioxide filter bed
  • Optional automatic working/flushing head in front of automatic valves
  • Filter tank 
  • Lower filtering crepina
  • Packaged and assembled ready for shipment anywhere in the world

 

Contact us without obligation by phone or email for any technical advice or purchase of our equipment.